COMTEC® 6000
The fast and fail-safe InSitu O2 & COe Analyzer
In the overview
O2 analyzer with integrated COe sensor for precise combustion optimization
-
Both sensors installed directly in the flue gas
-
Use enables a reduction in fuel and emissions
- Technical data
- Description
- Solutions
Technical data
Process gas temperature |
max. 500 °C to 1400 °C (with cooling protection tube) |
Measuring principle O₂ | Zirconium oxide |
Immersion depth/material | 440 mm / 900 mm / 1820 mm, 500 mm / 1000 with cooling protection tube, stainless steel (SS316TI) |
Measuring principle COe | MXP (mixed potential) |
Ambient temperature | Probe: -40°C to +80°C | Electronics: -20°C to +55°C |
O₂ - Measuring ranges | Two freely selectable measuring ranges: 0-2 Vol.% to 0-25 Vol.% (others on request) |
COe - Measuring ranges | 0 to 5000 ppm |
Housing | Probe: IP65 | Electronics: IP66 |
COMTEC 6000 is an in-situ gas analyzer for measuring oxygen and COe (the sum of unburned molecules such as carbon monoxide, methane, or hydrogen) in flue and process gases. This enables redundant measurement of both gases with high accuracy in real time, enabling efficient combustion optimization. This is achieved by combining the MXP sensor for COe analysis with the MLT sensor technology for calculating the oxygen content.
Both sensors are located within the process, as the probe is installed directly in the flue gas duct. Precise flue gas analysis can therefore take place continuously, resulting in this flue gas measuring device's very high response speed to changes in gas composition compared to extractive analyzers.
The design of this analyzer was particularly focused on low maintenance, minimal calibration effort, and complete user-friendliness. Furthermore, high investment and maintenance costs, especially compared to extractive analyzers, can be avoided.
Product downloads
Enquire online now
COMTEC® 6000
Please use our online inquiry form or send us an email to sales@enotec.de. We look forward to hearing from you and your inquiry.
Do you have any questions? Talk to us.
Certified safety.
Tested quality.
Our equipment meets the highest requirements.

Suitability test in accordance with
DIN EN 15267

Quality management in accordance with
DIN ISO 9001:2015

ATEX test certificate
Our focus has always been on performance and quality
Since 1980, ENOTEC has specialized in the manufacture of devices for gas analysis.