COMTEC® 6000 DustEx provides permanent and reliable gas analysis in Ex zones 21/22 with high dust loads. The DustEx probe is extremely robust and withstands the abrasive forces in high dust atmospheres.
Information
The standard InSitu analyzer system for use in dust explosion zones 21/22 is COMTEC® 6000 DustEx. In accordance to the tough demands placed on measuring systems in high dust processes, the DustEx is ATEX certified to II 2D Ex tb IIIC T133°C/T141°C Db.
Being able to precisely determine the proportion of oxygen and COe in flue gas is the starting point for the safe and optimized operation of incinerators, as oxygen and COe are dependent to one another within a combustion process. Undesirable developments can thus be identified and rectified earlier, before any damage is caused.
The COMTEC® 6000 DustEx is also available for O2 only measurements.
Technical Data
- Insertion depth of probe
-
540 mm
960 mm - O2 / COe ranges
-
0 - 25 % O2
min.: 0-1000 ppm /
max.: 0-5000 ppm COe
(others on request) - Sensor accuracy O2
-
< 0.5 % of measured value or
0.02 Vol % O2
(higher value valid) - Sensor accuracy COe
- better 5 % of range end
- Reaction time
- < 1 sec. (on test gas)
- Process gas temperature
-
max. 500 °C
max. 1400 °C (with cooling protection tube) - Ambient temperature
-
-20 °C to 70 °C (probe)
-20 °C to 55 °C (electronic unit) - Interface
- MODBUS RTU via RS232/RS485, HART, FIELDBUS, ENOTEC REMOTE
- IP code
-
IP65 (probe)
IP66 (electronic unit)
Applications
- Energy optimization
- Emission measurements
- Power generation
- Waste incineration
- Combustion control
Features
- InSitu measurement in real-time
- Overview of calibration history
- ATEX certified for zones 21/22
- Low-maintenance
- Self-monitoring
- Sensor life expectancy on display
- Gas tight sensor construction
ENOTEC REMOTE