Spare Probes
|
Westinghouse
Part Number USA
|
Westinghouse
Part Number European
|
Spare Probes
|
ENOTEC
Part Number
|
| 6631D65G01 |
1L01250G01 |
Model 132 |
KES 132 |
6630D10G21
6630D14G21 F/A |
1U03039G21 F/A
1U03039G16 F/A
1W04024G01 F/A |
Model 218- 18" |
KES 2001 |
6630D10G22
6630D14G22 F/A |
1U03039G22 F/A
1U03039G17 F/A
1W04024G02 F/A |
Model 218- 3ft |
KES 2002 |
6630D10G23
6630D14G23 F/A |
1U03039G23 F/A
1U03039G18 F/A
1W04024G03 F/A |
Model 218- 6ft |
KES 2003 |
6630D10G24
6630D14G24 F/A |
1U03039G24 F/A
1U03039G19 F/A
1W04024G04 F/A |
Model 218- 9ft |
KES 2004 |
6630D10G25
6630D14G25 F/A |
1U03039G25 F/A
1U03039G20 F/A
1W04024G05 F/A |
Model 218- 12ft |
KES 2005 |
| 9700D86G01..G16 |
9700D86G07
9700D86G22 F/A |
Model 3000-18" |
KES 2001 |
| 9700D86G02..G17 |
9700D86G08
9700D86G23 F/A |
Model 3000-3ft |
KES 2002 |
| 9700D86G03..G18 |
9700D86G09
9700D86G24 F/A |
Model 3000-6ft |
KES 2003 |
| 9700D86G04..G19 |
9700D86G35
9700D86G47 F/A |
Model 3000-9ft |
KES 2004 |
| 9700D86G05..G20 |
9700D86G36
9700D86G48 F/A |
Model 218-12ft |
KES2005 |
Note: When selecting the ENOTEC Probe, ensure that you also select the
correct filter head assembly to suit the application. Alternatively, the
customer can re-use the existing Model 132/218 Westinghouse Filter Head
Assembly depending on condition. Flame Arrestor type filter heads are
shown with the suffix F/A.
Probe Heaters
|
Westinghouse
Part Number
|
Heater - Length
|
ENOTEC
Part Number
|
1L01748G01 or
263C303H06 |
Model 132 -12" |
HEI 132x |
| 2831A68G01 |
Model 218 -18" |
HEI -2001 |
| 2831A68G02 |
Model 218 -3ft |
HEI -2002 |
| 2831A68G03 |
Model 218 -6ft |
HEI -2003 |
| 2831A68G04 |
Model 218 -9ft |
HEI -2004 |
| 2831A68G05 |
Model 218 -12ft |
HEI -2005 |
| 771B614H01 |
Support Support Sleeve |
HZH -0001 |
Thermocouples
|
Westinghouse
Part Number
|
Thermocouples
|
ENOTEC
Part Numbers
|
| 771B800G06 |
T/C Model 132 |
MT2-132x |
| 771B800G01 |
T/C Model 218 -18" |
MT2-2001 |
| 771B800G02 |
T/C Model 218 -3ft |
MT2-2002 |
| 771B800G03 |
T/C Model 218 -6ft |
MT2-2003 |
| 771B800G03 |
T/C Model 218 -9ft |
MT2-2004 |
| 771B800G04 |
T/C Model 132 -12ft |
MT2-2005 |
Note: The ENOTEC Thermocouple is a conventional twin element Nickel-Chromium/Nickel "type K" t/c with an Inconel 600 outer sheath,
but manufactured as a single leg. It therefore only uses one hole in the
ceramic rod in either the Westinghouse or ENOTEC probes.
Tested Sensors
|
Westinghouse
Part Number
|
Tested Sensor
|
ENOTEC
Part Number
|
| 1N04001G01 |
Model 218- 18" |
KES 2001 |
| 1N04001G02 |
Model 218- 3ft |
KES 2002 |
| 1N04001G03 |
Model 218- 6ft |
KES 2003 |
| 1N04001G04 |
Model 218- 9ft |
KES 2004 |
| 1N04001G05 |
Model 218- 12ft |
KES 2005 |
Cell Kits
|
Westinghouse
Part Number
|
Replaceable
Cell kits
|
ENOTEC
Part Number
|
| 6296A04G01 - G06 |
Model 225 Cell Kits |
Z02 - 0001 (MLT option) |
| 6296A04G08 |
Model 225 - 18" |
Z02 - 0001 (MLT option) |
| 6296A04G09 |
Model 225 - 3ft |
Z02 - 0001 (MLT option) |
| 6296A04G10 |
Model 225 - 6ft |
Z02 - 0001 (MLT option) |
| 6296A04G11 |
Model 225 - 9ft |
Z02 - 0001 (MLT option) |
| 6296A04G12 |
Model 225 - 12ft |
Z02 - 0001 (MLT option) |
Note: The Westinghouse Model 218 does not have an exchangeable measuring
cell. For a short time Westinghouse manufactured a Model 225 similar to
the Model 218 which had a replaceable cell. The ENOTEC Z02 -0001 is the
direct equivalent having both a 4 holes and 2 hole flange fixing with
screws so as to fit existing ENOTEC or Model 225 probes. It is supplied
with Cell Cap, Screws and S/S Gasket.
New MLT Cells available for harsh and sulphur applications.
Filter Head Assemblies
|
Westinghouse
Part Number
|
Filter Head Assembly
(Ceramic Filter)
|
ENOTEC
Part Number
|
| 263468G01 |
Standard Type |
KES -132010 |
| 263459G01 |
With Flame Arrestor |
KES -132060 |
| 263C302G07 |
Standard Type |
KES -2000100 |
| 263C284G06 |
With Flame Arrestor |
KES -2000400 |
| 263C284G03 +G05 |
With Flame Arrestor |
KES -2000400 |
| 1N04016G01 |
With Flame Arrestor |
KES -2000400 |
| 2831A99G02 |
Gasket & Garter Seal Kit |
KES -2000100/400 |
| 2830A62H01 |
Heat Shield Gasket |
KES -2000100/400 |
| 170941-001 |
Garter Spring |
KES -2000100/400 |
Note: The Westinghouse filter head assembly used a gasket and garter
spring seal to prevent unfiltered flue gases from entering the support/protection
tube and possible corrosion of the probe. The ENOTEC filter head assembly uses
a stainless steel collar to seal the inside of the protection tube. This
has been found to be more reliable without the need for consumable parts.
Therefore it is recommended that an ENOTEC Filter Head assembly be used
as an upgrade where possible.
Filter & Cement kits
|
Westinghouse
Part Number
|
Filter Kit
(ceramic Type)
|
ENOTEC
Part Number
|
| 6292A74G02 |
Model 132 Std Head |
KEF - 1321 |
| 6292A74G01 |
Model 132 F/A Head |
KEF - 200x |
| 6292A74G01 |
Model 218 F/A Head |
KEF - 200x |
Note: Other filter materials are available from ENOTEC to suit the customer
application - please refer to the price list for details.
Miscellaneous Parts
|
Westinghouse
Part Number
|
Item
|
ENOTEC
Part Number
|
| 3534B68H03 |
Ceramic Rod -
12" |
KER - 132x |
| 3534B68H01 |
Ceramic Rod - 18" |
KER - 2001 |
| 3534B68H02 |
Ceramic Rod - 3ft |
KER - 2002 |
| 771B614H01 |
Heater Support |
HZH - 0001 |
| 6276A74H03 |
Cap Nut |
EDV - 0001 |
| 1546B63H01 |
Flange Gasket - for model 132 |
FLD - 132x |
| 263C136H01 |
Flange Gasket - for model 218 |
FLD - 200x |
Probe Protection shields
|
Westinghouse
Part Number
|
Protection Shield for
|
ENOTEC
Part Number
|
| 263C276G01 |
Model 218 - 18" |
KES -2000001 |
| 6630G07G01 |
Model 218 - 3ft |
KES -2000002 |
| 6630G07G02 |
Model 218 - 6ft |
KES -2000003 |
| 6630G07G03 |
Model 218 - 9ft |
KES -2000004 |
| 6630G07G04 |
Model 218 - 12ft |
KES -2000005 |
Note: The Westinghouse Shields are all made from Stainless Steel 316, ENOTEC also uses 316, but they are also available in Inconel 625 for harsher
processes.
Shield Accessories
|
Westinghouse
Part Number
|
Accessories
|
ENOTEC
Part Number
|
| 2826A64G02 |
Adaptor Plate - 18" |
ASR - 1320 |
| 2826A64G01 |
Adaptor Plate - 3ft -12ft |
ADP - 2000 |
Test Gas Kits
|
Westinghouse
Part Number
|
Test Gas
Kits &
Spare Bottles
|
ENOTEC
Part Number
|
| 6296A27G01 |
2 Bottles Kit (0.4% & 8% O2) |
GAS - 0001 |
| 67-F8185G01 |
3 Bottles Kit |
not available |
| 3530B07G03 |
2% O2 Spare Bottle |
GAS - 0003 |
| 3530B07G02 |
8% O2 Spare Bottle |
GAS - 0004 |
Note: ENOTEC only use a two bottle kit. As the reference point, ENOTEC uses Instrument Air which is known to be 20.95%
Oxygen.
Digital Electronics
|
Westinghouse
Part Number
|
Electronic Package
|
ENOTEC
Part Number
|
| 1U05618G02 |
Basic for Model 132 |
SME - 5 |
| 1U05600G09 |
Universal for 218 |
SME - 5 |
| 1U03083G07 |
EExd for Model 218 |
SME - 5 |
| 1U03070G04 |
CPU Mother Board |
SME - 5 |
| 1N04816G02 |
CPU Mother Board |
SME - 5 |
| 1N04811G01 |
CPU Mother Board |
SME - 5 |
| 1U05600G10 |
Universal for 218 |
SME - 5 |
Note: The use of the ENOTEC SME 5 series electronics with existing Westinghouse
probes will greatly enhance the accuracy of reading from the instrument
due to the superior Microprocessor heater control. Optimum accuracy of
+/- 1% of reading can be obtained by using the full ENOTEC system that
uses a superior probe heater control circuit via the SME 5 microprocessor
electronics.
Analogue Electronics
|
Westinghouse
Part Number
|
Cards for Analogue Electronics
|
ENOTEC
Part Number
|
| 2822A25G03 |
Temp. Control Card |
SME - 5 |
| 7510E56G01 |
P.S./Lin/Iso. Card |
SME - 5 |
| 1500D41G01 |
P.S./Amplifier Card |
SME - 5 |
|
Westinghouse
Part Number
|
Transformer -
in field housing
|
ENOTEC
Part Number
|
| 4517C12 |
General purpose |
TRA - 0013 |
Note: The Westinghouse Analogue boards are now obsolete. Spare cards are not available.
Depending on the location of the electronics the SME-5 may need
to be housed in a EExd field housing. Please refer to your local ENOTEC office or representative for details. SME-5 is also available in standard
IP54, NEMA 12 and 19" rack control room housings.
Cables
|
Westinghouse
Part Number
|
Cable Item
|
ENOTEC
Part Number
|
| 6296A16H01 |
Probe Cable / Metre |
FEP - 0001 |
| 1L02639H01 |
Reinforced Probe Cable for hazardous areas / Metre |
FEP - 0004 |
Air Set Parts
|
Westinghouse
Part Number
|
Component
|
ENOTEC
Part Number
|
| 771B635H01 |
Flowmeter 0-10 scfh |
DFM - 0037 (25-250 l/h) |
| 771B635H02 |
Flowmeter 0-2 scfh |
DFM - 0036 (4-40 l/h) |
| 4505C21G01 |
Regulator |
P303 |
| 2075431-006 |
Pressure Gauge |
P304
|
Note: The ENOTEC air set can be installed, as an option, in the SME 5
field electronic housing.
Probe Repair Kits
|
Westinghouse
Part Number
|
Probe Repair Kit
|
ENOTEC
Part Number
|
| 6296A93G02 |
Model 132 |
SIK - 1321 |
| 2831A68G01 |
Model 218 & 225 18" |
SIK - 2001 |
| 2831A68G02 |
Model 218 & 225 3ft |
SIK - 2002 |
| 2831A68G03 |
Model 218 & 225 6ft |
SIK - 2003 |
| 2831A68G04 |
Model 218 & 225 9ft |
SIK - 2004 |
| 2831A68G05 |
Model 218 & 225 12ft |
SIK - 2005 |
Note:
1) The ENOTEC part number above is for a complete inner probe assembly.
This includes ceramic rods, clips, screws etc., Platinum wire and pad,
heater, T/C, all mounted and assembled ready to insert into a 132, 218,
218A, 225, 240 style probe. This assembly does not include the field replaceable
measuring cell.
2) Modifications can be made to existing 218 "fixed cell" probes
to convert them into a field replaceable type using the ENOTEC cell, but
consideration should be given to the overall age and condition of the
equipment to reach the best option for the customer in terms of value,
cost effectiveness and performance. Please consult your service centre.
|